LABORATORY PRESS MIGNON MAX 40 E
Built in a compact and elegant steel structure coated with epoxy paint baked at 180°C.
It is entirely hydraulically operated and fully automatic except for loading the material to be pressed.
It is a tool designed for intermittent use, suitable for producing laboratory samples.
The pressing force is applied via a hydraulic cylinder located on the upper part of the press, to which a special pad is mounted.
The mold, placed on the work surface, is manually filled with the powder to be pressed.
After pressing, the resulting sample is extracted by means of
a piston located at the bottom.
MAXIMUM SOFT THICKNESS: 27 mm
Technical specifications
TECHNICAL SPECIFICATIONS
• Hydraulically operated pressing cylinder (40 tons)
• Hydraulically operated extractor cylinder
• Hydraulic power unit with automatic adjustment of working pressure using a proportional valve (30-350 bar)
• Electronic control unit that allows the press to operate automatically
• Lexan front guard with safety microswitch
• 20 L hydraulic oil tank
• Bimetallic fixed-point safety thermostat 70°C
• Pressure transducer 0-400 bar
• Dual hydraulic circuit for independent calibration of sample extraction force (factory setting)
TOUCH SCREEN ELECTRONIC CONTROL UNIT
• Pressure display on the display
• Programming of up to three soft material thicknesses
• Manual programming of working pressure
• Programming of the dwell time at the maximum set pressure
• Prinogramming of deaeration
• Storing of mold dimensions
• Programming of the desired kg/cm2 pressing force
• Display of the kg/cm2 force and the corresponding working pressure, depending on the format
• Automatic pressing cycle start
• Ready for Ethernet and USB ports for Industry 4.0